Property
Min
Max
Test Method
Viscosity, Saybolt Furol at 25°C, SFS
20
100
ASTM D7496
Storage stability test, 24-h, %
1
ASTM D6930
Demulsibility, 35mL, 0.8% dioctyl sodium sulfosuccinate, %
ASTM D6936
Particle charge test
Positive
Positive
ASTM D7402
Sieve test, %
0.1
ASTM D6933
Cement mixing test,%
2
ASTM D6935
Distillation:
Oil distillate, by volume of emulsion, %
12
ASTM D6997
Residue, %
57
ASTM D6997
Tests on residue from distillation test:
Penetration, 25°C (77°F), 100g, 5s
40
90
ASTM D5
Ductility, 25°C (77°F), 5cm/min, cm
40
ASTM D113
Solubility in trichloroethylene, %
97.5
ASTM D2042

Cationic Bitumen (Asphalt) Emulsion Grade CSS-1h

Property
Min
Max
Test Method
Viscosity, Saybolt Furol at 25°C, SFS
20
100
ASTM D7496
Storage stability test, 24-h, %
1
ASTM D6930
Demulsibility, 35mL, 0.8% dioctyl sodium sulfosuccinate, %
ASTM D6936
Coating ability and water resistance:
Particle charge test
Positive
Positive
ASTM D7402
Sieve test, %
0.1
ASTM D6933
Cement mixing test,%
2
ASTM D6935
Distillation:
Oil distillate, by volume of emulsion, %
ASTM D6997
Residue, %
57
ASTM D6997
Tests on residue from distillation test:
Penetration, 25°C (77°F), 100g, 5s
100
250
ASTM D5
Ductility, 25°C (77°F), 5cm/min, cm
40
ASTM D113
Solubility in trichloroethylene, %
97.5
ASTM D2042

Cationic Bitumen (Asphalt) Emulsion Grade CSS-1

Property
Min
Max
Test Method
Viscosity, Saybolt Furol at 50°C, SFS
100
400
ASTM D7496
Storage stability test, 24-h, %
1
ASTM D6930
Demulsibility, 35mL, 0.8% dioctyl sodium sulfosuccinate, %
40
ASTM D6936
Coating ability and water resistance:
Particle charge test
Positive
Positive
ASTM D7402
Sieve test, %
0.1
ASTM D6933
Distillation:
Oil distillate, by volume of emulsion, %
3
ASTM D6997
Residue, %
65
ASTM D6997
Tests on residue from distillation test:
Penetration, 25°C (77°F), 100g, 5s
100
250
ASTM D5
Ductility, 25°C (77°F), 5cm/min, cm
40
ASTM D113
Solubility in trichloroethylene, %
97.5
ASTM D2042

Cationic Bitumen (Asphalt) Emulsion Grade CRS-2

Property
Min
Max
Test Method
Viscosity, Saybolt Furol at 50°C, SFS
20
100
ASTM D7496
Storage stability test, 24-h, %
1
ASTM D6930
Demulsibility, 35mL, 0.8% dioctyl sodium sulfosuccinate, %
40
ASTM D6936
Coating ability and water resistance:
Particle charge test
Positive
Positive
ASTM D74020
Sieve test, %
0.1
ASTM D6933
Distillation:
Oil distillate, by volume of emulsion, %
3
ASTM D6997
Residue, %
60
ASTM D6997
Tests on residue from distillation test:
Penetration, 25°C (77°F), 100g, 5s
100
250
ASTM D5
Ductility, 25°C (77°F), 5cm/min, cm
40
ASTM D113
Solubility in trichloroethylene, %
97.5
ASTM D2042

Cationic Bitumen (Asphalt) Emulsion Grade CRS-1

Property
Min
Max
Test Method
Viscosity, Saybolt Furol at 25°C, SFS
ASTM D7496
Viscosity, Saybolt Furol at 50°C, SFS
50
450
ASTM D7496
Storage stability test, 24-h, %
1
ASTM D6930
Demulsibility, 35mL, 0.8% dioctyl sodium sulfosuccinate, %
ASTM D6936
Coating ability and water resistance:
Coating, dry aggregate
Good
ASTM D244
Coating, after spraying
Fair
ASTM D244
Coating, wet aggregate
Fair
ASTM D244
Coating, after spraying
Fair
ASTM D244
Particle charge test
Positive
Positive
ASTM D244
Sieve test, %
0.1
ASTM D6933
Cement mixing test,%
ASTM D6935
Distillation:
Oil distillate, by volume of emulsion, %
12
ASTM D6997
Residue, %
65
ASTM D6997
Tests on residue from distillation test:
Penetration, 25°C (77°F), 100g, 5s
40
90
ASTM D5
Ductility, 25°C (77°F), 5cm/min, cm
40
ASTM D113
Solubility in trichloroethylene, %
97.5
ASTM D2042

Cationic Bitumen (Asphalt) Emulsion Grade CMS-2h

Property
Min
Max
Test Method
Viscosity, Saybolt Furol at 25°C, SFS
ASTM D7496
Viscosity, Saybolt Furol at 50°C, SFS
50
450
ASTM D7496
Storage stability test, 24-h, %
1
ASTM D6930
Demulsibility, 35mL, 0.8% dioctyl sodium sulfosuccinate, %
ASTM D6936
Coating ability and water resistance:
Coating, dry aggregate
Good
ASTM D244
Coating, after spraying
Fair
ASTM D244
Coating, wet aggregate
Fair
ASTM D244
Coating, after spraying
Fair
ASTM D244
Particle charge test
Positive
Positive
ASTM D244
Sieve test, %
0.1
ASTM D6933
Cement mixing test,%
ASTM D6935
Distillation:
Oil distillate, by volume of emulsion, %
12
ASTM D6997
Residue, %
65
ASTM D6997
Tests on residue from distillation test:
Penetration, 25°C (77°F), 100g, 5s
100
250
ASTM D5
Ductility, 25°C (77°F), 5cm/min, cm
40
ASTM D113
Solubility in trichloroethylene, %
97.5
ASTM D2042

Cationic Bitumen (Asphalt) Emulsion Grade CMS-2

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
800
1,600
ASTM D2170
Flash Point (Cleveland open cup), °C [°F]
93[200]
ASTM D92
Distillation test:
Total distillate to 360°C [680°F], volume %
2
12
ASTM D402
Solubility in trichloroethylene, %,
99
ASTM D2042
Kinematic viscosity on distillation residue at 60°C [140°F], mm2/s
2000
16,000
ASTM D2170
Asphalt residue:
Residue of 100 penetration, %
70
ASTM D243
Ductility of 100 penetration residue at 25°C [77°F], cm
100
ASTM D113
Water, %
0.5
ASTM D95

Cutback Bitumen SC-800

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
70
140
ASTM D2170
Flash Point (Cleveland open cup), °C [°F]
66[150]
ASTM D92
Distillation test:
Total distillate to 360°C [680°F], volume %
10
30
ASTM D402
Solubility in trichloroethylene, %,
99
ASTM D2042
Kinematic viscosity on distillation residue at 60°C [140°F], mm2/s
400
7000
ASTM D2170
Asphalt residue:
Residue of 100 penetration, %
50
ASTM D243
Ductility of 100 penetration residue at 25°C [77°F], cm
100
ASTM D113
Water, %
0.5
ASTM D95

Cutback Bitumen SC-70

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
3000
6000
ASTM D2170
Flash Point (Cleveland open cup), °C [°F]
107[225]
ASTM D92
Distillation test:
Total distillate to 360°C [680°F], volume %
5
ASTM D402
Solubility in trichloroethylene, %,
99
ASTM D2042
Kinematic viscosity on distillation residue at 60°C [140°F], mm2/s
4000
35,000
ASTM D2170
Asphalt residue:
Residue of 100 penetration, %
80
ASTM D243
Ductility of 100 penetration residue at 25°C [77°F], cm
100
ASTM D113
Water, %
0.5
ASTM D95

Cutback Bitumen SC-3000

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
250
500
ASTM D2170
Flash Point (Cleveland open cup), °C [°F]
79[175]
ASTM D92
Distillation test:
Total distillate to 360°C [680°F], volume %
4
20
ASTM D402
Solubility in trichloroethylene, %,
99
ASTM D2042
Kinematic viscosity on distillation residue at 60°C [140°F], mm2/s
800
10,000
ASTM D2170
Asphalt residue:
Residue of 100 penetration, %
60
ASTM D243
Ductility of 100 penetration residue at 25°C [77°F], cm
100
ASTM D113
Water, %
0.2
ASTM D95

Cutback Bitumen SC-250

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
800
1600
ASTM D2170
Flash point (Tag open-cup), °C [°F]
27+[80+]
ASTM D3143
Distillate test: Distillate, volume percent of total distillate to 360°C [680°F]:
to 190°C [374°F]
ASTM D402
to 225°C [437°F]
15
ASTM D402
to 260°C [500°F]
45
ASTM D402
to 316°C [600°F]
75
ASTM D402
Residue from distillation to 360°C [680°F], percent volume by difference
75
ASTM D402
Tests on residue from distillation test:
Penetration at 25°C,
80
120
ASTM D5
Ductility at 25°C [77°F], cm
100
ASTM D113
Solubility in trichloroethylene, %
99
ASTM D2042
Water, %
0.2
ASTM D95

Cutback Bitumen RC-800

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
70
140
ASTM D2170
Flash point (Tag open-cup), °C [°F]
ASTM D3143
Distillate test: Distillate, volume percent of total distillate to 360°C [680°F]:
to 190°C [374°F]
10
ASTM D402
to 225°C [437°F]
50
ASTM D402
to 260°C [500°F]
70
ASTM D402
to 316°C [600°F]
85
ASTM D402
Residue from distillation to 360°C [680°F], percent volume by difference
55
ASTM D402
Tests on residue from distillation test:
Penetration at 25°C,
80
120
ASTM D5
Ductility at 25°C [77°F], cm
100
ASTM D113
Solubility in trichloroethylene, %
99
ASTM D2042
Water, %
0.2
ASTM D95

Cutback Bitumen RC-70

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
3000
6000
ASTM D2170
Flash point (Tag open-cup), °C [°F]
27+[80+]
ASTM D3143
Distillate test: Distillate, volume percent of total distillate to 360°C [680°F]:
to 190°C [374°F]
ASTM D402
to 225°C [437°F]
ASTM D402
to 260°C [500°F]
25
ASTM D402
to 316°C [600°F]
70
ASTM D402
Residue from distillation to 360°C [680°F], percent volume by difference
80
ASTM D402
Tests on residue from distillation test:
Penetration at 25°C,
80
120
ASTM D5
Ductility at 25°C [77°F], cm
100
ASTM D113
Solubility in trichloroethylene, %
99
ASTM D2042
Water, %
0.2
ASTM D95

Cutback Bitumen RC-3000

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
250
500
ASTM D2170
Flash point (Tag open-cup), °C [°F]
27+[80+]
ASTM D3143
Distillate test: Distillate, volume percent of total distillate to 360°C [680°F]:
to 190°C [374°F]
ASTM D402
to 225°C [437°F]
35
ASTM D402
to 260°C [500°F]
60
ASTM D402
to 316°C [600°F]
60
90
ASTM D402
Residue from distillation to 360°C [680°F], percent volume by difference
65
ASTM D244
Tests on residue from distillation test:
Penetration at 25°C,
80
120
ASTM D5
Ductility at 25°C [77°F], cm
100
ASTM D113
Solubility in trichloroethylene, %
99
ASTM D2042
Water, %
0.2
ASTM D95

Cutback Bitumen RC-250

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
800
1600
ASTM D2170
Flash point (Tag open-cup), °C [°F]
66[150]
ASTM D3143
Distillate test: Distillate, volume percent of total distillate to 360°C [680°F]:
to 225°C [437°F]
ASTM D402
to 260°C [500°F]
40
ASTM D402
to 316°C [600°F]
45
85
ASTM D402
Residue from distillation to 360°C [680°F], percent volume by difference
75
ASTM D402
Tests on residue from distillation test:
Penetration at 25°C,
120
250
ASTM D5
Ductility at 25°C [77°F], cm
100
ASTM D113
Solubility in trichloroethylene, %
99
ASTM D2042
Water, %
0.2
ASTM D95

Cutback Bitumen MC-800

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
70
140
ASTM D2170
Flash point (Tag open-cup), °C [°F]
38[100]
ASTM D3143
Distillate test: Distillate, volume percent of total distillate to 360°C [680°F]:
to 225°C [437°F]
25
ASTM D402
to 260°C [500°F]
10
70
ASTM D402
to 316°C [600°F]
65
93
ASTM D402
Residue from distillation to 360°C [680°F], percent volume by difference
55
ASTM D402
Tests on residue from distillation test:
Penetration at 25°C,
120
300
ASTM D5
Ductility at 25°C [77°F], cm
100
ASTM D113
Solubility in trichloroethylene, %
99
ASTM D2042
Water, %
0.2
ASTM D95

Cutback Bitumen MC-70

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
3000
6000
ASTM D2170
Flash point (Tag open-cup), °C [°F]
66[150]
ASTM D3143
Distillate test: Distillate, volume percent of total distillate to 360°C [680°F]:
to 225°C [437°F]
ASTM D402
to 260°C [500°F]
15
ASTM D402
to 316°C [600°F]
15
75
ASTM D402
Residue from distillation to 360°C [680°F], percent volume by difference
80
ASTM D244
Tests on residue from distillation test:
Penetration at 25°C,
120
250
ASTM D5
Ductility at 25°C [77°F], cm
100
ASTM D113
Solubility in trichloroethylene, %
99
ASTM D2042
Water, %
0.2
ASTM D95

Cutback Bitumen MC-3000

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
30
60
ASTM D2170
Flash point (Tag open-cup), °C [°F]
38[100]
ASTM D3143
Distillate test: Distillate, volume percent of total distillate to 360°C [680°F]:
to 225°C [437°F]
35
ASTM D402
to 260°C [500°F]
30
75
ASTM D402
to 316°C [600°F]
75
95
ASTM D402
Residue from distillation to 360°C [680°F], percent volume by difference
50
ASTM D402
Tests on residue from distillation test:
Penetration at 25°C,
120
300
ASTM D5
Ductility at 25°C [77°F], cm
100
ASTM D113
Solubility in trichloroethylene, %
99
ASTM D2042
Water, %
0.2
ASTM D95

Cutback Bitumen MC-30

Property
Min
Max
Test Method
Kinematic viscosity at 60°C [140°F], mm2/s
250
500
ASTM D2170
Flash point (Tag open-cup), °C [°F]
66[150]
ASTM D3143
Distillate test: Distillate, volume percent of total distillate to 360°C [680°F]:
to 225°C [437°F]
20
ASTM D402
to 260°C [500°F]
5
55
ASTM D402
to 316°C [600°F]
60
90
ASTM D402
Residue from distillation to 360°C [680°F], percent volume by difference
67
ASTM D244
Tests on residue from distillation test:
Penetration at 25°C,
120
300
ASTM D5
Ductility at 25°C [77°F], cm
100
ASTM D113
Solubility in trichloroethylene, %
99
ASTM D2042
Water, %
0.2
ASTM D95

Cutback Bitumen MC-250

Bitumen Grade 80/100 Specifications

ITEM
SPECIFICATION
UNIT
RESULT/TEST METHOD (ASTM)
1
SPECIFIC GRAVITY@25/25°C
1.00-1.05
D. 70
2
PENETRATION @ 25°C
80/100
D. 5
3
SOFTENING POINT(°C)
45/52
D36
4
DUCTILITY @ 25° C
100 MIN
D-113
5
LOSS ON HEATING (WT)%
0.5 MAX
D-6
6
DROP IN PENETRATION AFTER HEATING %
20 Max
D-6 & D-5
7
FLASH POINT °C
225 Min
D-92
8
SOLUBILITY IN CS2(WT)%
99.5 Min
D-4
9
ORGANIC MATTER INSOLUBLE IN Cs2(wt)%
0.2 Max
D-4
ITEM
SPECIFICATION
UNIT
RESULT/TEST METHOD (ASTM)
1
SPECIFIC GRAVITY@25/25°C
1.01/1.05
D. 70
2
PENETRATION @ 25°C
85/100
D. 5
3
SOFTENING POINT
45/52
D. 36
4
DUCTILITY @ 25° C
100 MIN
D. 113
5
LOSS ON HEATING (WT)%
0.5 MAX
D. 6
6
FLASH POINT
225 MIN
D. 92
7
SOLUBILITY IN CS2 (WT)%
99.5 Max
D. 4
8
ORGANIC MATTER
0.2 MAX
D. 4
9
INSOLUBLE IN CS2 (WT)%
10
DROP IN PENETRATION AFTER HEATING %
20 MAX
D-6& D-5
11
SPOT TEST
NEGATIVE
A.A.S.H.O.T.102

Bitumen Grade 85/100 Specifications

ITEM
SPECIFICATION
UNIT
RESULT/TEST METHOD (ASTM)
1
SPECIFIC GRAVITY@25/25°C
1.01/1.04
D. 70
2
PENETRATION @ 25°C
100/120
D. 5
3
SOFTENING POINT
42/49
D. 36
4
DUCTILITY @ 25° C
100 MIN
D. 113
5
LOSS ON HEATING (WT)%
0.2 MAX
D. 6
6
FLASH POINT
250 MIN
D. 92
7
SOLUBILITY IN CS2 (WT)%
99.5 Max
D. 4
8
ORGANIC MATTER
— MAX
D. 4
9
INSOLUBLE IN CS2 (WT)%
10
DROP IN PENETRATION AFTER HEATING %
20 MAX
D-6& D-5
11
SPOT TEST
NEGATIVE
A.A.S.H.O.T.102

Bitumen Grade 100/120 Specifications

ITEM
SPECIFICATION
UNIT
RESULT/TEST METHOD (ASTM)
1
SPECIFIC GRAVITY @ 25/25°C
1.00-1.06
D-70
2
PENETRATION @25°C
60/70
D-5
3
SOFTENING POINT(°C)
49/56
D36
4
DUCTILITY @ 25°C
100 Min
D-113
5
LOSS ON HEATING (WT)%
0.2 Max
D-6
6
DROP IN PENETRATION AFTER HEATING %
20 Max
D-6 & D-5
7
FLASH POINT °C
250 Min
D-92
8
SOLUBILITY IN CS2(WT)%
99.5 Min
D-4
9
SPOT TEST
NEGATIVE
*A.A.S.H.O.T.102

Bitumen Grade 60/70 Specifications

ITEM
SPECIFICATION
TEST METHOD
UNIT
RESULT
1
Penetration @ 25°C
ASTM D5
0.1 mm
64
2
Flash Point
ASTM D92
°C
316
3
Spot Test
A.A.S.H.O.T.102
NEGATIVE
4
Absolute Viscosity @ 60°C
ASTM D2171
Poise
2086
5
Kinematic Viscosity @ 135°C
ASTM D2170
CST.
355.6
6
Softening Point
ASTM D36
°C
49.4
7
Rolling Thin Film Oven Test
ASTM 2872
8
Retained Penetration after RTFOT
ASTM D5
%
78.1
9
Kinematic Viscosity @ 135°C
ASTM D2170
CST.
488.6
10
Change of mass
ASTM 2872
%WT. D-6& D-5
0.12
11
Absolute Viscosity @ 60°C
ASTM D2171
Poise
3964
12
Softening Point
ASTM D36
°C
51.2
13
Increase Softening Point
ASTM D36
°C
1.8

***Bitumen Grade 50/70 Specifications

Analysis
Unit
Limit
Test Method
Density@25°C
Kg/m³
1010-1060
ASTM D70 or D3289
Penetration@25°C
mm/10
40-50
ASTM D5
Softening Point
°C
52-60
ASTM D36
Ductility@25°C
cm
100min
ASTM D113
Loss on Heating
wt%
0.2max
ASTM D6
Drop in Penteration after Heating
%
20max
ASTM D5
Flash Point
°C
232min
ASTM D92
Solubility in Trichloroethylene
wt%
99.0min
ASTM D2042
Spot Test
Negative
A.A.S.H.O.T.102
Viscosity@60°C
P
4000±800
ASTM D2171
Viscosity@135°C
cSt
400min
ASTM D2170
TEST ON RESIDUE FROM THIN FILM OVEN TEST ( ASTMD1754)
ANALYSIS
UNIT
LIMIT
TEST METHOD
RESTAINEDPENETRATION AFTER (T.F.O.T), %
%
58 MIN
ASTM D5
DUCTILITY, (25ºC), 5CM/MIN, CM AFTER TFOT
CM
50
ASTM D113
VISCOSITY @ 60 ºC
P
20000 MAX
ASTM D 2171

Bitumen grade 40/50 Specifications

ITEM
SPECIFICATION
UNIT
RESULT/TEST METHOD (ASTM)
1
SPECIFIC GRAVITY@25/25°C
1.01/1.05
D. 70
2
PENETRATION @ 25°C
30/40
D. 5
3
SOFTENING POINT
55/63
D. 36
4
DUCTILITY @ 25° C
100 MIN
D. 113
5
LOSS ON HEATING (WT)%
0.2 MAX
D. 6
6
FLASH POINT
250 MIN
D. 92
7
SOLUBILITY IN CS2 (WT)%
99.5 Max
D. 4
8
ORGANIC MATTER
0.2 MAX
D. 4
9
INSOLUBLE IN CS2 (WT)%
10
DROP IN PENETRATION AFTER HEATING %
20 MAX
D-6& D-5
11
SPOT TEST
NEGATIVE
A.A.S.H.O.T.102

Bitumen Grade 30/40 Specifications

Property
Units
VG-20
Test Methods
Absolute viscosity at 60°C
P
3200-4800
IS 1206
Kinematic viscosity at 135°C, Min
cSt
min400
IS 1206
Flash point (Cleveland open cup), Min
°C
min220
IS 1209
Solubility in trichloroethylene, Min
%Wt
min99
IS 1206
Softening point (R&B), Min
°C
min50
IS 1205
Penetration at 25°C, 100g, 5sec, Min
0.1MM
30-50
IS 1203
Tests on residue from thin film oven test:
– Viscosity ratio at 60°C, Max
max4
IS 1206
– Ductility at 25°C, Min
CM
min25
IS 1208

Viscosity Grade Bitumen VG40

Property
Units
VG-20
Test Methods
Absolute viscosity at 60°C
P
2400-3600
IS 1206
Kinematic viscosity at 135°C, Min
cSt
min350
IS 1206
Flash point (Cleveland open cup), Min
°C
min220
IS 1209
Solubility in trichloroethylene, Min
%Wt
min99
IS 1206
Softening point (R&B), Min
°C
min47
IS 1205
Penetration at 25°C, 100g, 5sec, Min
0.1MM
50-70
IS 1203
Tests on residue from thin film oven test:
– Viscosity ratio at 60°C, Max
max4
IS 1206
– Ductility at 25°C, Min
CM
min40
IS 1208

Viscosity Grade Bitumen VG30

Property
Units
VG-20
Test Methods
Absolute viscosity at 60°C
P
1600-2400
IS 1206
Kinematic viscosity at 135°C, Min
cSt
min300
IS 1206
Flash point (Cleveland open cup), Min
°C
min220
IS 1209
Solubility in trichloroethylene, Min
%Wt
min99
IS 1206
Softening point (R&B), Min
°C
min45
IS 1205
Penetration at 25°C, 100g, 5sec, Min
0.1MM
60-80
IS 1203
Tests on residue from thin film oven test:
– Viscosity ratio at 60°C, Max
max4
IS 1206
– Ductility at 25°C, Min
CM
min50
IS 1208

Viscosity Grade Bitumen VG20

Property
Units
VG-10
Test Methods
Absolute viscosity at 60°C
P
800-1200
IS 1206
Kinematic viscosity at 135°C, Min
cSt
min250
IS 1206
Flash point (Cleveland open cup), Min
°C
min220
IS 1209
Solubility in trichloroethylene, Min
%Wt
min99
IS 1206
Softening point (R&B), Min
°C
min40
IS 1205
Penetration at 25°C, 100g, 5sec, Min
0.1MM
80-100
IS 1203
Tests on residue from thin film oven test:
– Viscosity ratio at 60°C, Max
max4
IS 1206
– Ductility at 25°C, Min
CM
min75
IS 1208

Viscosity Grade Bitumen VG10

CHARACTERISTICS
VG-10
VG-20
VG-30
VG-40
Absolute viscosity.60ºC .poises. min
800
1600
2400
3200
Kinematic Viscosity.135 ºC .CST. min
250
300
350
400
Flash point. C. min
220
220
220
220
Solubility in trichloroethylene. % . min
99
99
99
99
Penetration a 25 ºC
80-100
60-80
50-70
40-60
Softening point. C. min.
40
45
47
50
Test on residue from thin film over test / RTFOT:
i. Viscosity ratio at 60 ºC. max
4
4
4
4
ii. Ductility at 25 ºC. cm. min. after thin film over test
75
50
40
25

Viscosity Grade Bitumen